Nissan Primera P12. Instruction - page 82

POWER DOOR LOCK SYSTEM

BL-37

C

D

E

F

G

H

J

K

L

M

A

B

BL

INTERNAL SWITCH (POWER WINDOW MAIN SWITCH)

1.

CHECK TRUNK OR BACK DOOR RELEASE SWITCH INPUT SIGNAL

With CONSULT-II

Check trunk or back door release switch input signal “INT TRUNK REL” in “DATA MONITOR” mode with CON-
SULT- II.

Without CONSULT- II

Check voltage between smart entrance control unit harness connector and ground.

OK or NG

OK

>> Trunk or back door release switch is OK.

NG

>> GO TO 2

2.

CHECK TRUNK OR BACK DOOR RELEASE SWITCH

1.

Turn ignition switch OFF.

2.

Disconnect power window main switch (trunk or back door release switch) connector.

3.

Check continuity between power window main switch (trunk or back door release switch) terminals 3 and
12.

OK or NG

OK

>> Check the following.

Harness for open or short between power window
main switch (trunk or back door release switch) and
smart entrance control unit

Power window main switch (trunk or back door
release switch) ground circuit

NG

>> Replace power window main switch (trunk or back door release switch).

Release switch is pushed (open):

INT TRUNK REL ON

Release switch is released (close):

INT TRUNK REL OFF

SIIA1606E

Connector

Terminal (wire color)

Release switch

Voltage (V)

(Approx.)

(+)

(–)

M41

19 (BR/W)

Ground

Pushed

0

Released

5

SIIA1607E

Terminals

Release switch

Continuity

3

12

Pushed

Yes

Released

No

MIIB0457E

BL-38

POWER DOOR LOCK SYSTEM

Trunk Release Actuator Check (Sedan)

EIS005H3

1.

CHECK POWER SUPPLY CIRCUIT

Check voltage between trunk release actuator harness connector B30 terminal 2 and ground.

OK or NG

OK

>> GO TO 2.

NG

>> Check the following.

10A fuse (No. 3, located in the fusible link and fuse
box).

Harness for open or short between trunk release
actuator and fuse.

2.

CHECK TRUNK RELEASE ACTUATOR CIRCUIT

1.

Turn ignition switch OFF.

2.

Disconnect trunk release actuator and smart entrance control unit harness connector.

3.

Check continuity between trunk release actuator harness con-
nector B30 terminal 1 and smart entrance control unit harness
connector M43 terminal 57.

OK or NG

OK

>> GO TO 3.

NG

>> Repair or replace harness between smart entrance control unit and trunk release actuator.

3.

CHECK SMART ENTRANCE CONTROL UNIT OUTPUT SIGNAL

1.

Connect trunk release actuator and smart entrance control unit connector.

2.

Check voltage between smart entrance control unit connector and ground.

OK or NG

OK

>> Replace trunk release actuator.

NG

>> Replace smart entrance control unit.

2 (P) - Ground

: Battery voltage

MIIB0458E

1 (G/B) - 57 (G/B)

: Continuity should exist.

SIIA1587E

Connector

Terminal (wire color)

Condition

Voltage (V)

(Approx.)

(+)

(–)

M43

57 (G/B)

Ground

Trunk release

switch: ON

0

Other than above

Battery voltage

MIIB0474E

POWER DOOR LOCK SYSTEM

BL-39

C

D

E

F

G

H

J

K

L

M

A

B

BL

Back Door Release Actuator Check (Wagon)

EIS005H4

1.

CHECK POWER SUPPLY CIRCUIT

1.

Turn ignition switch OFF.

2.

Disconnect back door release actuator harness connector.

3.

Check voltage between back door release actuator harness connector D90 terminal 3 and ground.

OK or NG

OK

>> GO TO 2.

NG

>> Check the following.

10A fuse (No. 3, located in the fusible link and fuse
box).

Harness for open or short between back door release
actuator and fuse.

2.

CHECK BACK DOOR RELEASE ACTUATOR CIRCUIT

1.

Disconnect smart entrance control unit harness connector.

2.

Check continuity between back door release actuator harness
connector D90 terminal 4 and smart entrance control unit har-
ness connector M43 terminal 57.

OK or NG

OK

>> GO TO 3.

NG

>> Repair or replace harness between smart entrance control unit and back door release actuator.

3.

CHECK SMART ENTRANCE CONTROL UNIT OUTPUT SIGNAL

1.

Connect trunk release actuator and smart entrance control unit connector.

2.

Check voltage between smart entrance control unit connector and ground.

OK or NG

OK

>> Replace back door release actuator.

NG

>> Replace smart entrance control unit.

3 (P) - Ground

: Battery voltage

MIIB0459E

4 (G/B) - 57 (G/B)

: Continuity should exist.

MIIB0460E

Connector

Terminal (wire color)

Condition

Voltage (V)

(Approx.)

(+)

(–)

M43

57 (G/B)

Ground

Back door

release switch:

ON

0

Other than above

Battery voltage

MIIB0474E

BL-40

POWER DOOR LOCK SYSTEM

Back Door Release Actuator Check (Hatch back)

EIS0061I

1.

CHECK POWER SUPPLY CIRCUIT

Check voltage between back door release actuator harness connector B57 terminal 3 and ground.

OK or NG

OK

>> GO TO 2.

NG

>> Check the following.

10A fuse (No. 3, located in the fusible link and fuse
box).

Harness for open or short between back door release
actuator and fuse.

2.

CHECK BACK DOOR RELEASE ACTUATOR CIRCUIT

1.

Turn ignition switch.

2.

Disconnect back door release actuator and smart entrance control unit harness connector.

3.

Check continuity between back door release actuator harness
connector B57 terminal 4 and smart entrance control unit har-
ness connector M43 terminal 57.

OK or NG

OK

>> GO TO 3.

NG

>> Repair or replace harness between smart entrance control unit and back door release actuator.

3.

CHECK SMART ENTRANCE CONTROL UNIT OUTPUT SIGNAL

1.

Connect trunk release actuator and smart entrance control unit connector.

2.

Check voltage between smart entrance control unit connector and ground.

OK or NG

OK

>> Replace back door release actuator.

NG

>> Replace smart entrance control unit.

3 (P) - Ground

: Battery voltage

MIIB0461E

4 (G/B) - 57 (G/B)

: Continuity should exist.

MIIB0462E

Connector

Terminal (wire color)

Condition

Voltage (V)

(Approx.)

(+)

(–)

M43

57 (G/B)

Ground

Back door

release switch:

ON

0

Other than above

Battery voltage

MIIB0474E