Nissan Primera P12. Instruction - page 82
POWER DOOR LOCK SYSTEM
BL-37
C
D
E
F
G
H
J
K
L
M
A
B
BL
INTERNAL SWITCH (POWER WINDOW MAIN SWITCH)
1.
CHECK TRUNK OR BACK DOOR RELEASE SWITCH INPUT SIGNAL
With CONSULT-II
Check trunk or back door release switch input signal “INT TRUNK REL” in “DATA MONITOR” mode with CON-
SULT- II.
Without CONSULT- II
Check voltage between smart entrance control unit harness connector and ground.
OK or NG
OK
>> Trunk or back door release switch is OK.
NG
>> GO TO 2
2.
CHECK TRUNK OR BACK DOOR RELEASE SWITCH
1.
Turn ignition switch OFF.
2.
Disconnect power window main switch (trunk or back door release switch) connector.
3.
Check continuity between power window main switch (trunk or back door release switch) terminals 3 and
12.
OK or NG
OK
>> Check the following.
●
Harness for open or short between power window
main switch (trunk or back door release switch) and
smart entrance control unit
●
Power window main switch (trunk or back door
release switch) ground circuit
NG
>> Replace power window main switch (trunk or back door release switch).
Release switch is pushed (open):
INT TRUNK REL ON
Release switch is released (close):
INT TRUNK REL OFF
SIIA1606E
Connector
Terminal (wire color)
Release switch
Voltage (V)
(Approx.)
(+)
(–)
M41
19 (BR/W)
Ground
Pushed
0
Released
5
SIIA1607E
Terminals
Release switch
Continuity
3
12
Pushed
Yes
Released
No
MIIB0457E
BL-38
POWER DOOR LOCK SYSTEM
Trunk Release Actuator Check (Sedan)
EIS005H3
1.
CHECK POWER SUPPLY CIRCUIT
Check voltage between trunk release actuator harness connector B30 terminal 2 and ground.
OK or NG
OK
>> GO TO 2.
NG
>> Check the following.
●
10A fuse (No. 3, located in the fusible link and fuse
box).
●
Harness for open or short between trunk release
actuator and fuse.
2.
CHECK TRUNK RELEASE ACTUATOR CIRCUIT
1.
Turn ignition switch OFF.
2.
Disconnect trunk release actuator and smart entrance control unit harness connector.
3.
Check continuity between trunk release actuator harness con-
nector B30 terminal 1 and smart entrance control unit harness
connector M43 terminal 57.
OK or NG
OK
>> GO TO 3.
NG
>> Repair or replace harness between smart entrance control unit and trunk release actuator.
3.
CHECK SMART ENTRANCE CONTROL UNIT OUTPUT SIGNAL
1.
Connect trunk release actuator and smart entrance control unit connector.
2.
Check voltage between smart entrance control unit connector and ground.
OK or NG
OK
>> Replace trunk release actuator.
NG
>> Replace smart entrance control unit.
2 (P) - Ground
: Battery voltage
MIIB0458E
1 (G/B) - 57 (G/B)
: Continuity should exist.
SIIA1587E
Connector
Terminal (wire color)
Condition
Voltage (V)
(Approx.)
(+)
(–)
M43
57 (G/B)
Ground
Trunk release
switch: ON
0
Other than above
Battery voltage
MIIB0474E
POWER DOOR LOCK SYSTEM
BL-39
C
D
E
F
G
H
J
K
L
M
A
B
BL
Back Door Release Actuator Check (Wagon)
EIS005H4
1.
CHECK POWER SUPPLY CIRCUIT
1.
Turn ignition switch OFF.
2.
Disconnect back door release actuator harness connector.
3.
Check voltage between back door release actuator harness connector D90 terminal 3 and ground.
OK or NG
OK
>> GO TO 2.
NG
>> Check the following.
●
10A fuse (No. 3, located in the fusible link and fuse
box).
●
Harness for open or short between back door release
actuator and fuse.
2.
CHECK BACK DOOR RELEASE ACTUATOR CIRCUIT
1.
Disconnect smart entrance control unit harness connector.
2.
Check continuity between back door release actuator harness
connector D90 terminal 4 and smart entrance control unit har-
ness connector M43 terminal 57.
OK or NG
OK
>> GO TO 3.
NG
>> Repair or replace harness between smart entrance control unit and back door release actuator.
3.
CHECK SMART ENTRANCE CONTROL UNIT OUTPUT SIGNAL
1.
Connect trunk release actuator and smart entrance control unit connector.
2.
Check voltage between smart entrance control unit connector and ground.
OK or NG
OK
>> Replace back door release actuator.
NG
>> Replace smart entrance control unit.
3 (P) - Ground
: Battery voltage
MIIB0459E
4 (G/B) - 57 (G/B)
: Continuity should exist.
MIIB0460E
Connector
Terminal (wire color)
Condition
Voltage (V)
(Approx.)
(+)
(–)
M43
57 (G/B)
Ground
Back door
release switch:
ON
0
Other than above
Battery voltage
MIIB0474E
BL-40
POWER DOOR LOCK SYSTEM
Back Door Release Actuator Check (Hatch back)
EIS0061I
1.
CHECK POWER SUPPLY CIRCUIT
Check voltage between back door release actuator harness connector B57 terminal 3 and ground.
OK or NG
OK
>> GO TO 2.
NG
>> Check the following.
●
10A fuse (No. 3, located in the fusible link and fuse
box).
●
Harness for open or short between back door release
actuator and fuse.
2.
CHECK BACK DOOR RELEASE ACTUATOR CIRCUIT
1.
Turn ignition switch.
2.
Disconnect back door release actuator and smart entrance control unit harness connector.
3.
Check continuity between back door release actuator harness
connector B57 terminal 4 and smart entrance control unit har-
ness connector M43 terminal 57.
OK or NG
OK
>> GO TO 3.
NG
>> Repair or replace harness between smart entrance control unit and back door release actuator.
3.
CHECK SMART ENTRANCE CONTROL UNIT OUTPUT SIGNAL
1.
Connect trunk release actuator and smart entrance control unit connector.
2.
Check voltage between smart entrance control unit connector and ground.
OK or NG
OK
>> Replace back door release actuator.
NG
>> Replace smart entrance control unit.
3 (P) - Ground
: Battery voltage
MIIB0461E
4 (G/B) - 57 (G/B)
: Continuity should exist.
MIIB0462E
Connector
Terminal (wire color)
Condition
Voltage (V)
(Approx.)
(+)
(–)
M43
57 (G/B)
Ground
Back door
release switch:
ON
0
Other than above
Battery voltage
MIIB0474E