Nissan Primera P12. Instruction - page 46
AUDIO
AV-27
C
D
E
F
G
H
I
J
L
M
A
B
AV
Terminal No. (wire
color)
Item
Signal
input/
output
Condition
Voltage
Example of symptom
( + )
( – )
Ignition
switch
Operation
1(Y/R)
Ground
Illumination
signal
Input
OFF
Lighting
switch is ON
(position 1).
Battery voltage
Audio unit illumination
does not come on
when lighting switch is
ON (position 1).
Turn lighting
switch OFF.
Approx. 3.0V or less
2(P)
Ground
ACC power
Input
ACC
-
Battery voltage
Audio unit operation is
not possible.
3(Y)
Ground
Battery power
Input
OFF
-
Battery voltage
Audio unit operation is
not possible.
4(Y)
Ground
Battery power
Input
OFF
-
Battery voltage
Audio unit operation is
not possible.
6(L)
5(LG)
Speaker out-
put (front LH)
Output
ON
Receive
radio broad-
cast
No sound from front LH
speaker.
8(BR)
7(BR/
W)
Speaker out-
put (front RH)
Output
ON
Receive
radio broad-
cast
No sound from front
RH speaker.
10(LG)
9(B/Y)
Speaker out-
put (rear LH)
Output
ON
Receive
radio broad-
cast
No sound from rear LH
speaker.
12(L)
11(P)
Speaker out-
put (rear RH)
Output
ON
Receive
radio broad-
cast
No sound from rear RH
speaker.
14 (W)
13 (B)
CD sound sig-
nal (LH)
Input
ON
Play CD.
CD sound is not heard
from LH speaker.
SKIA0177E
SKIA0177E
SKIA0177E
SKIA0177E
SKIA0195E
AV-28
AUDIO
16 (G)
15 (R)
CD sound sig-
nal (RH)
Input
ON
Play CD.
CD sound is not heard
from RH speaker.
20 (R/G)
Ground
Communica-
tion signal
(CHG REQ)
Input
ON
Insert/eject
magazine.
CD Auto changer oper-
ation is not possible.
21 (R/L)
Ground
Communica-
tion signal
(CHG to
COMB)
Input
ON
Insert/eject
magazine.
CD Auto changer oper-
ation is not possible.
22 (R/W)
Ground
Communica-
tion signal
(COMB to
CHG)
Output
ON
Press the
disc switch.
CD Auto changer oper-
ation is not possible.
27 (L/B)
Ground
vehicle speed
signal (2-
pulse)
Input
ON
When vehi-
cle speed
signal is
approx, 20
km/h
(12MPH)
Speed dependent vol-
ume control does not
operate.
28 (Y)
Ground
Immobilizer
-
-
-
-
Audio is locked
29 (PU)
Ground
Illumination
control signal
Input
ON
Illumination
control
switch is
operated by
lighting
switch in 1st
position.
Changes between approx. 0 and
approx. 12V.
Audio unit illumination
cannot be controlled.
Terminal No. (wire
color)
Item
Signal
input/
output
Condition
Voltage
Example of symptom
( + )
( – )
Ignition
switch
Operation
SKIA0195E
SKIA0196E
SKIA0197E
SKIA0198E
ELF1080D
AUDIO
AV-29
C
D
E
F
G
H
I
J
L
M
A
B
AV
38 (BR)
37(Y)
Voice guide
signal (with
navigation
system)
Input
ON
Press the
“voice”
switch.
Only route guide and
operation guide are not
heard.
39(B)
-
Shield ground
(with naviga-
tion system)
-
-
-
-
-
43(P)
Ground
Communica-
tion signal (-)
Input/
output
ON
-
System does not work
properly.
44(L)
Ground
Communica-
tion signal (+)
Input/
output
ON
-
System does not work
properly.
45
-
Shield ground
-
-
-
-
-
46(B)
-
Shield ground
-
-
-
-
-
47(G)
Ground
Communica-
tion signal (-)
(with naviga-
tion system)
Input/
output
ON
-
System does not work
properly.
48(R)
Ground
Communica-
tion signal (+)
(with naviga-
tion system)
Input/
output
ON
-
System does not work
properly.
Terminal No. (wire
color)
Item
Signal
input/
output
Condition
Voltage
Example of symptom
( + )
( – )
Ignition
switch
Operation
SKIA0171J
SKIA0176E
SKIA0175E
SKIA0176E
SKIA0175E
AV-30
AUDIO
Terminals and Reference Value for Sub-woofer
EKS009J4
Terminal No. (wire
color)
Item
Signal
input/
output
Condition
Voltage
Example of symptom
( + )
( – )
Ignition
switch
Operation
2(L)
1(LG)
Audio sound
signal (LH)
Input
ON
Receive radio
broadcast
Audio sound not heard
sub-woofer.
3(B)
Ground
Ground
-
ON
-
-
-
4(P)
Ground
ACC power
Input
ACC
-
Battery voltage
Sub-woofer does not
work.
6(L)
5(P)
Audio sound
signal (RH)
Input
ON
Receive radio
broadcast
Audio sound not heard
sub-woofer.
SKIA0177E
SKIA0177E