Mitsubishi 380. Instruction - page 34
SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)
54B-133
STEP 6. Check the wiring harness between ETACS-ECU
connector C-219 (terminal 12) and front door lock actuator
(RH) connector E-05 (terminal 4).
NOTE: Also check intermediate connector C-12 and junction
block connector C-211 for loose, corroded, or damaged termi-
nals, or terminals pushed back in the connector. If intermediate
connector C-12 or junction block connector C-211 is damaged,
repair or replace the damaged component(s) as described in
GROUP 00E, Harness Connector Inspection
Q: Is the wiring harness between ETACS-ECU connector
C-219 (terminal 12) and front door lock actuator (RH)
connector E-05 (terminal 4) in good condition?
YES : Replace the ETACS-ECU. Verify that all the doors
can be locked and unlocked normally.
NO : The wiring harness may be damaged or the
connector(s) may have loose, corroded or damaged
terminals, or terminals pushed back in the connector.
Repair or replace the damaged component(s). Verify
that the central door locking system works normally.
54DB014A
CONNECTOR: C-219
JUNCTION BLOCK SIDE
JUNCTION BLOCK
(REAR VIEW)
16DB308A
E-05 (B)
HARNESS SIDE
CONNECTOR: E-05
16DB310A
CONNECTOR: C-12
SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)
54B-134
STEP 7. Check front door lock actuator (LH) connector
E-15 for loose, corroded or damaged terminals, or
terminals pushed back in the connector.
Q: Is front door lock actuator (LH) connector E-15 in good
condition?
YES : Go to Step 8.
NO : Repair or replace the damaged component(s). Refer
to GROUP 00E, Harness Connector Inspection
P.00E-2
. Verify that all the doors can be locked and
unlocked normally.
STEP 8. Check the front door lock actuator (LH).
Remove the front door lock actuator (LH). The illustration
shows when the door lock actuator is viewed from inside the
door. Refer to GROUP 42
− Door Handle and Latch
P.42-46
.
Q: Is the front door lock actuator (LH) normal?
YES : Go to Step 9.
NO : Replace the front door lock actuator (LH). Verify that
all the doors can be locked and unlocked normally.
16DB320A
CONNECTOR: E-15
E-15 (B)
HARNESS SIDE
LEVER
POSITION
BATTERY
CONNECTION
LEVER
OPERATION
At the "LOCK"
position
• Connect terminal 4
to the negative
battery terminal
• Connect terminal 6
to the positive
battery terminal
The lever moves
from the "LOCK"
position to the
"UNLOCK"
position.
At the
"UNLOCK"
position
• Connect terminal 6
to the negative
battery terminal
• Connect terminal 4
to the positive
battery terminal
The lever moves
from the
"UNLOCK" position
to the "LOCK"
position.
16DB321A
1 2 3
4 5 6
VIEW A
B
LOCK
LEVER
UNLOCK
SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)
54B-135
STEP 9. Check ETACS-ECU connector C-219 for loose,
corroded or damaged terminals, or terminals pushed back
in the connector.
Q: Is ETACS-ECU connector C-219 in good condition?
YES : Go to Step 10.
NO : Repair or replace the damaged component(s). Refer
to GROUP 00E, Harness Connector Inspection
P.00E-2
. Verify that all the doors can be locked and
unlocked normally.
STEP 10. Check the wiring harness between ETACS-ECU
connector C-219 (terminals 12 and 13) and front door lock
actuator (LH) connector E-15 (terminals 4 and 6).
54DB014A
CONNECTOR: C-219
JUNCTION BLOCK SIDE
JUNCTION BLOCK
(REAR VIEW)
54DB014A
CONNECTOR: C-219
JUNCTION BLOCK SIDE
JUNCTION BLOCK
(REAR VIEW)
16DB320A
CONNECTOR: E-15
E-15 (B)
HARNESS SIDE
SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)
54B-136
NOTE: Also check intermediate connector C-26 and junction
block connector C-211 for loose, corroded, or damaged termi-
nals, or terminals pushed back in the connector. If intermediate
connector C-26 or junction block connector C-211 is damaged,
repair or replace the damaged component(s) as described in
GROUP 00E, Harness Connector Inspection
Q: Is the wiring harness between ETACS-ECU connector
C-219 (terminals 12 and 13) and front door lock actuator
(LH) connector E-15 (terminals 4 and 6) in good
condition?
YES : Replace the ETACS-ECU. Verify that all the doors
can be locked and unlocked normally.
NO : The wiring harness may be damaged or the
connector(s) may have loose, corroded or damaged
terminals, or terminals pushed back in the connector.
Repair the wiring harness as necessary.
STEP 11. Check rear door lock actuator (LH) connector
E-18 for loose, corroded or damaged terminals, or
terminals pushed back in the connector.
Q: Is rear door lock actuator (LH) connector E-18 in good
condition?
YES : Go to Step 12.
NO : Repair or replace the damaged component(s). Refer
to GROUP 00E, Harness Connector Inspection
P.00E-2
. Verify that all the doors can be locked and
unlocked normally.
16DB322A
CONNECTOR:C-26
16DB323A
E-18 (B)
HARNESS SIDE
CONNECTOR: E-18