Mitsubishi 380. Instruction - page 29
SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)
54B-113
STEP 2. Using diagnostic tool MB991958, diagnose the
CAN bus line.
CAUTION
To prevent damage to diagnostic tool MB991958, always
turn the ignition switch to the "LOCK" (OFF) position
before connecting or disconnecting diagnostic tool
MB991958.
(1) Connect diagnostic tool MB991958. Refer to "How to
connect SWS monitor
P.54B-13
."
(2) Turn the ignition switch to the "ON" position.
(3) Diagnose the CAN bus line.
(4) Turn the ignition switch to the "LOCK" (OFF) position.
Q: Is the CAN bus line found to be normal?
YES : Go to Step 3.
NO : Repair the CAN bus line (Refer to GROUP 54C,
Diagnosis
P.54C-13
).
STEP 3. Using diagnostic tool MB991958, read the multi
center display diagnostic trouble code.
Check that a multi center display DTC is set.
(1) Turn the ignition switch to the "ON" position.
(2) Check if the multi center display DTC is set.
(3) Turn the ignition switch to the "LOCK" (OFF) position.
Q: Is the DTC set?
YES : Diagnose the multi center display unit (Refer to
GROUP 54A, Diagnosis
P.54A-254
).
NO : Go to Step 4.
00DB076A
MB991910
DATA LINK
CONNECTOR
MB991824
MB991827
SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)
54B-114
STEP 4. Use diagnostic tool MB991958 to select "ECU
COMM Check" on the SWS monitor display.
Check the ETACS-ECU.
CAUTION
Connect special tool MB991910 before connecting special
tool MB991812. Be sure to connect special tool MB991806
after turning on special tool MB991824.
(1) Connect the SWS monitor. Refer to "How to connect SWS
monitor
P.54B-13
."
(2) Turn the ignition switch to the "ON" position.
(3) Operate diagnostic tool MB991958 according to the
procedure below to display "ECU COMM Check."
a. Select "Interactive Diagnosis."
b. Select "System Select."
c. Select "SWS."
d. Select "SWS MONITOR."
e. Select "ECU COMM Check."
(4) diagnostic tool MB991958 should show "OK" on the "ECU
COMM Check" menu for the "ETACS ECU" menu.
Q: Is "OK" displayed for the "ETACS ECU" menu?
YES : Go to Step 5.
NO : Refer to Inspection Procedure A-3 "Communication
with the ETACS-ECU is not possible
P.54B-74
."
00DB076A
MB991910
DATA LINK
CONNECTOR
MB991824
MB991827
AC302210
COLUMN SWITCH
CONNECTOR
COLUMN SWITCH
CONNECTOR AT
HARNESS SIDE
MB991812
AB
SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)
54B-115
STEP 5. Check the input signal by using "FUNCTION
DIAG." menu of the SWS monitor.
Turn the ignition switch to the "ON" position to check the input
signals from the following switches.
(1) Operate diagnostic tool MB991958 according to the
procedure below to display "OTHER ALARM."
a. Select "Interactive Diagnosis."
b. Select "System Select."
c. Select "SWS."
d. Select "SWS MONITOR."
e. Select "Function Diag."
f.
Select "BUZZER."
g. Select "OTHER ALARM."
(2) Check that normal conditions are displayed for the items
described in the table below.
NOTE: If the function switch of the multi center display is
operated, check that No.43 "BUZZER" is displayed as nor-
mal condition.
Q: Are normal conditions displayed for the "IG SW (IG1)"
and "BUZZER"?
Normal conditions are displayed for all the items :
Replace the ETACS-ECU. Verify that the multi center
display operating sound function works normally.
Normal condition is not displayed for "IG SW (IG1)" :
Refer to Inspection Procedure M-2 "ETACS-ECU
does not receive any signal from the ignition switch
(IG1)
P.54B-408
."
Normal condition is not displayed for "BUZZER" :
Replace the ETACS-ECU. Verify that the multi center
display operating sound function works normally.
ITEM NO.
ITEM NAME
NORMAL
CONDITION
ITEM 30
IG SW (IG1)
ON
ITEM 43
BUZZER
ON
00DB076A
MB991910
DATA LINK
CONNECTOR
MB991824
MB991827
AC302210
COLUMN SWITCH
CONNECTOR
COLUMN SWITCH
CONNECTOR AT
HARNESS SIDE
MB991812
AB
SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)
54B-116
INSPECTION PROCEDURE B-6: Tone Alarm: Turn-signal Lamp Buzzer Function does not Work
Normally.
NOTE: This troubleshooting procedure requires use
of diagnostic tool MB991958 and SWS monitor kit
MB991813. For details on how to use the SWS mon-
itor, refer to "How to connect SWS monitor
."
.
CIRCUIT OPERATION
The ETACS-ECU controls the turn-signal lamp
buzzer function, based on the switch signals below:
• Turn-signal lamp switch: ON
• Hazard switch: ON
.
TECHNICAL DESCRIPTION (COMMENT)
If the turn-signal lamp buzzer function does not work
normally, connector(s), wiring harness, the column
switch, the ETACS-ECU or the input signal circuit
may be defective.
.
TROUBLESHOOTING HINTS
• Refer to circuit diagrams GROUP-
90
• Refer to configuration diagrams GROUP-
80
• Trouble in input signal system
• The wiring harness or connectors may have
loose, corroded, or damaged terminals, or termi-
nals pushed back in the connector
• The ETACS-ECU may be defective
DIAGNOSIS
Required Special Tools:
• MB991223: Harness Set
• MB991958: diagnostic tool (MUT-III Sub Assembly)
• MB991824: Vehicle Communication Interface (V.C.I.)
• MB991827: MUT-III USB Cable
• MB991910: MUT-III Main Harness A
• MB991813: SWS Monitor Kit
• MB991806: SWS Monitor Cartridge
• MB991812: SWS Monitor Harness (For Column-ECU)
• MB991822: Test Probe Harness
STEP 1. Check the adjustment function.
Q: Has the turn-signal lamp buzzer function been enabled
by the adjustment function?
YES : Go to Step 2.
NO : Enable the turn-signal lamp buzzer function.
ETACS-
ECU
·
HAZARD WARNING LIGHT
SWITCH
·
TURN-SIGNAL LIGHT
SWITCH
Turn-signal Annunciation Function