Daewoo Korando. Instruction - page 353
REMOTE KEYLESS ENTRY AND ANTI-THEFT SYSTEM 9T-5
MAINTENANCE AND REPAIR
ON-VEHICLE SERVICE
REKES
1 REKES Receiver
2 Antenna
3 Bolt
4 Wiring Connector (6P)
9T-6 REMOTE KEYLESS ENTRY AND ANTI-THEFT SYSTEM
Input Memory
l
When the REKES transmitter is lost
1. Connect the battery terminal No.3 and REKES terminal No.4
which are on the diagnosis socket in engine room with service
lead wire.
2. Push the lock or unlock button on the REKES transmitter.
3. Input Memory and close all doors.
4. Check the operation of door locking system by pushing the
lock or unlock button on the REKES transmitter.
l
When the transmitter is faulty
1. Replace the REKES transmitter with a new one and connect
the wiring connector.
2. Set the input switch of the REKES receiver onto the No.1 or
No.2 position and push the lock or unlock button on the
REKES transmitter.
3. Set the input switch of the REKES receiver onto the central
position and close all doors.
4. Check the operation of door locking system by pushing the
lock or unlock button on the REKES transmitter.
1
REKES Transmitter
2
Input Switch of the REKES Receive
3
REKES Switch
REMOTE KEYLESS ENTRY AND ANTI-THEFT SYSTEM 9T-7
Characteristic Signal
1. Lock or unlock all doors according to the REKES signal
when the key is removed from the key hole.
2. Characteristic Signal : Right Picture
3. Time Interval
T1 : 0.05 ± 0.02sec.(lock signal)
T2 : 0.1 ± 0.02sec.(unlock signal)
T3 : within 0.25sec.
T4 : 0.5 ± 0.1sec.
T5 : within 0.35sec.
T6,T7 : 0.5 ± 0.1sec.
T8 : 1 ± 0.25sec.
Connector Appearance and Connecting Circuit
Pin No.
1
2
3
4
5
6
Connecting Circuit
B+
Memory Terminal
Key Reminder Switch
STICS
Ground
Memory Terminal
9T-8 REMOTE KEYLESS ENTRY AND ANTI-THEFT SYSTEM
FUNCTION DESCRIPTION
BURGLAR ALARM
Diagram for Burglar Alarm