2. EBS-2 CUSTOMER PARAMETERS

2.1 INTRODUCTION

Customer parameters
Customer parameters are the settings of an

electronic system. The customer parameters

permit adapting control functions of a system to

the customer's particular wishes and/or needs

within certain limits. The customer parameters

are stored in a list in the memory of the electronic

unit. Customer parameters can be modified using

the programming feature of DAVIE XD.

Programming using DAVIE XD is only possible if

the logged-in user has been registered as a

"Master Technician".

Note:

Erroneous settings of customer parameters may

affect the action of control functions to such an

extent that they function eratically or not at all.

After modification of the settings the (modified)

customer parameters must be stored in the

electronic unit using the programming function in

the customer parameter overview.

Customer parameter names and codes
Each customer parameter in a system has its

own name and code. The following explanation of

the customer parameters includes only the

codes. The availability of a customer parameter

in a system depends on the programmed

software in the electronic unit. The programmed

software depends on the vehicle configuration/

identity card data.

Standard values
Standard values, options and setting ranges may

vary according to the software variants of

DAVIE XD and the system. This is why they have

not been included in the following explanation of

the customer parameters.

EBS-2

2-2

©

EBS-2 customer parameters

DAVIE XD diagnostics manual

12

2.2

E

X

P

LANATORY

NOTES

TO EBS

-2 CUS

TOMER P

ARAMET

E

RS

EBS Customer

para

meter

c

o

de

Exp

la

n

atio

n

D

e

p

en

de

nc

es:

Notes

Minimum

va

lu

e to be

se

t:

Ma

ximum

value

to

b

e

set:

3

-0

1

T

his is

a

co

mfort

p

arameter settin

g which de

te

rmi

nes

the pul

sing "P-in

sh

ot"

to the draw

n

ve

hicle

.

0

b

ar

3.5

bar

The

pressure

pulse

activation

"P insh

ot" is on

ly avai

lab

le

on FT

ve

hicle

s an

d is

o

nly active if

a

dra

w

n vehicl

e

without EBS

syste

m

is coup

led

.

Thi

s setting can

be

ch

ange

d if:

-

there

is

a compl

aint re

lati

ng

to the towing

of

the

d

ra

w

n vehi

cl

e when

b

ra

king is sta

rte

d.

©

3-1

System inspection with DAVIE XD

EBS-2

DAVIE XD diagnostics manual

12

3. SYSTEM INSPECTION WITH DAVIE XD

3.1 GENERAL

If the vehicle has been modified and the

configuration changed, the electronic unit may

have to be re-programmed.

EBS-2

3-2

©

System inspection with DAVIE XD

12

DAVIE XD diagnostics manual

3.2 VSC CALIBRATION

Using DAVIE, the VSC calibration must be

activated after the following operations:

-

replacing EBS-2 electronic unit

-

replacing VSC module

-

changes to parameter setting

The slip indicator on the instrument panel will be

activated while the VSC is being calibrated and

will go off when VSC calibration has been

successfully completed.

When VSC calibration is active, a calibration error

code can also be displayed by means of DAVIE.

Note:

-

The slip indicator is not activated during VSC

calibration on vehicles with production date

<2004-21. On these vehicles the fact that the

calibration error code is no longer present on

DAVIE indicates that calibration has been

successfully completed.

-

VSC calibration takes place automatically

and is completed when the vehicle has been

driven a total of approximately 250 m in the

straight-ahead position. This distance of 250

m in the straight-ahead position does not

have to be covered in one go: the steering

wheel can be turned from time to time.

-

VSC control functions cannot be activated

while calibration is being carried out.